Industrial Rivet and Fastener Co
            Knowledge Base Freeset Cordless Tools Tool Models RK-7XX-3 Error Codes - On Screen Display

            Error PC

            Indication:
                  - Error PC message is shown on the tool on screen display.

            Description:
                  - Error PC can occur when their is messaging misalignment between tool and PC/Controller. 

            Possible Cause: 
                  A) Two replica tools are communicating on the same channel of the controller.
                  B)  PC/Controller has sent or received an unexpected message. 

            Remedy: 
                  A) Be sure only one tool per controller is powered at a time. 
                  B)  Restart the PFCS Connect Software, or a windows restart of the controller.  *Do not hard boot the PC with the controller switch.

            Updated: 02 Jan 2018 03:13 PM
            Helpful?  
            Help us to make this article better
            0 0